Videojet 1580 / 1860 / 1880

Videojet E15008: Viscometer Empty Time Too Long

Videojet manual Checked 2026-11-21
Quick answer Videojet E15008 means The viscometer failed to empty in time, so viscosity cannot be monitored..

What it means

The viscometer failed to empty in time, so viscosity cannot be monitored..

This page is generated from a public source (see below). It is a starting point, not a substitute for the service manual for your exact model and serial number.

Likely causes

  • Clogged viscometer drain
  • Thick ink
  • Blocked vent cross-connect
  • Valve leaking
  • Low-level probe fault
  • Defective IMB

What to check

  1. Contact your local Videojet Service representative

Parts and consumables

Parts

  • viscometer
  • valve
  • ink management board

Consumables

  • ink

FAQ

What does Videojet E15008 mean?

Videojet E15008 (Viscometer Empty Time Too Long) means: The viscometer failed to empty in time, so viscosity cannot be monitored.

What should I check first for Videojet E15008?

Start with: Contact your local Videojet Service representative.

When should I call a technician for Videojet E15008?

If the checks above do not clear the code, or the fault involves a board, pump, valve, heater, or EHT/HV component, stop and call a qualified technician. Do not keep a production line running on an unresolved fault.

Source: https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf — p. 9-13 “(E15008) Viscometer Empty Time Too Long”. Provenance tier: manual. Confidence: high. Diagnostic guidance only — always verify against the manual for your exact model.