Videojet 1580 / 1860 / 1880

Videojet E15007: Viscometer Fill Time Too Long

Videojet manual Checked 2026-11-21
Quick answer Videojet E15007 means The viscometer failed to fill in time, so viscosity cannot be monitored..

What it means

The viscometer failed to fill in time, so viscosity cannot be monitored..

This page is generated from a public source (see below). It is a starting point, not a substitute for the service manual for your exact model and serial number.

Likely causes

  • Clogged viscometer restrictor
  • High-level probe fault
  • Valve fault
  • Blocked vent
  • Defective IMB

What to check

  1. Run a hardware self-test on the ink system components

Parts and consumables

Parts

  • viscometer
  • valve
  • ink management board

Consumables

  • ink

FAQ

What does Videojet E15007 mean?

Videojet E15007 (Viscometer Fill Time Too Long) means: The viscometer failed to fill in time, so viscosity cannot be monitored.

What should I check first for Videojet E15007?

Start with: Run a hardware self-test on the ink system components.

When should I call a technician for Videojet E15007?

If the checks above do not clear the code, or the fault involves a board, pump, valve, heater, or EHT/HV component, stop and call a qualified technician. Do not keep a production line running on an unresolved fault.

Source: https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf — p. 9-13 “(E15007) Viscometer Fill Time Too Long”. Provenance tier: manual. Confidence: high. Diagnostic guidance only — always verify against the manual for your exact model.