Videojet 1580 / 1860 / 1880
Videojet E10690: Printhead 1 Valve Current Too Low
Quick answer
Videojet E10690 means Printhead valve drive current is too low for the number of valves in use..
What it means
Printhead valve drive current is too low for the number of valves in use..
This page is generated from a public source (see below). It is a starting point, not a substitute for the service manual for your exact model and serial number.
Likely causes
- Open circuit in one or more valves
- Defective MCB
What to check
- Stop the jet and run a hardware valve test
Parts and consumables
Parts
- printhead valves
- main control board
Consumables
- Not listed in the source.
FAQ
What does Videojet E10690 mean?
Videojet E10690 (Printhead 1 Valve Current Too Low) means: Printhead valve drive current is too low for the number of valves in use.
What should I check first for Videojet E10690?
Start with: Stop the jet and run a hardware valve test.
When should I call a technician for Videojet E10690?
If the checks above do not clear the code, or the fault involves a board, pump, valve, heater, or EHT/HV component, stop and call a qualified technician. Do not keep a production line running on an unresolved fault.
Source: https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf — p. 9-8 “(E10690) Printhead 1 Valve Current Too Low”.
Provenance tier: manual. Confidence: high. Diagnostic guidance only — always verify against the manual for your exact model.