Videojet 1580 / 1860 / 1880

Videojet E10681: Ink System Valve Current Too Low

Videojet manual Checked 2026-11-21
Quick answer Videojet E10681 means Valve drive current is too low for the number of valves in use..

What it means

Valve drive current is too low for the number of valves in use..

This page is generated from a public source (see below). It is a starting point, not a substitute for the service manual for your exact model and serial number.

Likely causes

  • Open circuit in one or more valves
  • Defective IMB

What to check

  1. Stop the jet and run a hardware valve test

Parts and consumables

Parts

  • ink system valves
  • ink management board

Consumables

  • ink

FAQ

What does Videojet E10681 mean?

Videojet E10681 (Ink System Valve Current Too Low) means: Valve drive current is too low for the number of valves in use.

What should I check first for Videojet E10681?

Start with: Stop the jet and run a hardware valve test.

When should I call a technician for Videojet E10681?

If the checks above do not clear the code, or the fault involves a board, pump, valve, heater, or EHT/HV component, stop and call a qualified technician. Do not keep a production line running on an unresolved fault.

Source: https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf — p. 9-8 “(E10681) Ink System Valve Current Too Low”. Provenance tier: manual. Confidence: high. Diagnostic guidance only — always verify against the manual for your exact model.