Videojet 1580 / 1860 / 1880
Videojet E10670: Viscometer Temperature Feedback Error
Quick answer
Videojet E10670 means Ambient and viscometer temperatures do not agree..
What it means
Ambient and viscometer temperatures do not agree..
This page is generated from a public source (see below). It is a starting point, not a substitute for the service manual for your exact model and serial number.
Likely causes
- Viscometer temperature sensor connection fault
What to check
- Switch the printer off and check the viscometer temperature sensor connection to the IMB
Parts and consumables
Parts
- viscometer
- temperature sensor
Consumables
- ink
FAQ
What does Videojet E10670 mean?
Videojet E10670 (Viscometer Temperature Feedback Error) means: Ambient and viscometer temperatures do not agree.
What should I check first for Videojet E10670?
Start with: Switch the printer off and check the viscometer temperature sensor connection to the IMB.
When should I call a technician for Videojet E10670?
If the checks above do not clear the code, or the fault involves a board, pump, valve, heater, or EHT/HV component, stop and call a qualified technician. Do not keep a production line running on an unresolved fault.
Source: https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf — p. 9-7 “(E10670) Viscometer Temperature Feedback Error”.
Provenance tier: manual. Confidence: high. Diagnostic guidance only — always verify against the manual for your exact model.