Domino A-Series (A100 / A200 / A300 / A400)
Domino Viscosity out of range: Viscosity out of range
Quick answer
Domino Viscosity out of range means Ink viscosity is out of range; printing is still possible but quality may drop..
What it means
Ink viscosity is out of range; printing is still possible but quality may drop..
This page is generated from a public source (see below). It is a starting point, not a substitute for the service manual for your exact model and serial number.
Likely causes
- Make-up cartridge empty or add solenoid failed
- Too many shutdowns caused low viscosity
- Ambient temperature wrong
What to check
- Replace the make-up cartridge or solenoid
- Let the printer run until ink recovers, or change the reservoir
- Confirm the ambient temperature is correct
Parts and consumables
Parts
- make-up cartridge
- make-up add solenoid
Consumables
- make-up fluid
- ink
FAQ
What does Domino Viscosity out of range mean?
Domino Viscosity out of range (Viscosity out of range) means: Ink viscosity is out of range; printing is still possible but quality may drop.
What should I check first for Domino Viscosity out of range?
Start with: Replace the make-up cartridge or solenoid. Then: Let the printer run until ink recovers, or change the reservoir. Then: Confirm the ambient temperature is correct.
When should I call a technician for Domino Viscosity out of range?
If the code returns after the checks above, or the printer develops a new fault, call a qualified technician.
Source: http://marking.com.ua/INSTRUKCII/MANUAL%20PRINTERA/Domino%20A-Series%20Operation%20and%20Maintenance%20Manual%20.pdf — p. 4--13 “Viscosity out of range”.
Provenance tier: manual. Confidence: high. Diagnostic guidance only — always verify against the manual for your exact model.