Domino A-Series (A100 / A200 / A300 / A400)
Domino Pump speed outside normal range: Pump speed outside normal range
Quick answer
Domino Pump speed outside normal range means The pump is compensating for excess pressure or pressure loss..
What it means
The pump is compensating for excess pressure or pressure loss..
This page is generated from a public source (see below). It is a starting point, not a substitute for the service manual for your exact model and serial number.
Likely causes
- Blockage or leak in the ink circuit
- Pump pressure set too high
What to check
- Check for blockages or leaks in the ink circuit
- Check and adjust the pressure
Parts and consumables
Parts
- ink pump
Consumables
- ink
FAQ
What does Domino Pump speed outside normal range mean?
Domino Pump speed outside normal range (Pump speed outside normal range) means: The pump is compensating for excess pressure or pressure loss.
What should I check first for Domino Pump speed outside normal range?
Start with: Check for blockages or leaks in the ink circuit. Then: Check and adjust the pressure.
When should I call a technician for Domino Pump speed outside normal range?
If the checks above do not clear the code, or the fault involves a board, pump, valve, heater, or EHT/HV component, stop and call a qualified technician. Do not keep a production line running on an unresolved fault.
Source: http://marking.com.ua/INSTRUKCII/MANUAL%20PRINTERA/Domino%20A-Series%20Operation%20and%20Maintenance%20Manual%20.pdf — p. 4--12 “Pump speed outside normal range”.
Provenance tier: manual. Confidence: high. Diagnostic guidance only — always verify against the manual for your exact model.