Domino Abnormal vacuum level: Abnormal vacuum level
What it means
Jet-pump flow is wrong: either low flow at low pump speed, or flow with the pump running at high speed..
This page is generated from a public source (see below). It is a starting point, not a substitute for the service manual for your exact model and serial number.
Likely causes
- Ink leakage in the feed circuit
- Partial blockage in the feed circuit or jet pump
- Air drawn into the feed circuit
What to check
- Look for and stop any ink leakage
- Check for a partial blockage in the feed circuit or jet pump
- Check for air leaking into the feed circuit
Parts and consumables
Parts
- jet pump
- feed circuit
Consumables
- ink
FAQ
What does Domino Abnormal vacuum level mean?
Domino Abnormal vacuum level (Abnormal vacuum level) means: Jet-pump flow is wrong: either low flow at low pump speed, or flow with the pump running at high speed.
What should I check first for Domino Abnormal vacuum level?
Start with: Look for and stop any ink leakage. Then: Check for a partial blockage in the feed circuit or jet pump. Then: Check for air leaking into the feed circuit.
When should I call a technician for Domino Abnormal vacuum level?
If the checks above do not clear the code, or the fault involves a board, pump, valve, heater, or EHT/HV component, stop and call a qualified technician. Do not keep a production line running on an unresolved fault.