# Videojet E6021: Initial Phasing Trim Failed

**Series:** Videojet 1650 / 1650 UHS / 1550  \
**Source tier:** manual  \
**Confidence:** high  \
**Citation:** p. 7-13 — "Initial Phasing Trim Failed"  \
**Last checked:** 2026-11-21

## What it means

The phasing trim at jet start-up failed because phase data could not be obtained.

## Likely causes

- Partly blocked or dirty nozzle
- Wet or dirty printhead

## What to check

- Back-flush the nozzle
- Clean the printhead and dry it completely
- After two failed attempts, use the service manual or call a Videojet engineer

## Parts

- nozzle
- printhead

## Consumables

- cleaning solution

## Source

- https://www.videojet.com/wp-content/uploads/dam/Countries/North%20America/Operator-Manuals/CIJ/1650-Operator-Manual.pdf

> Diagnostic guidance only. Verify against the service manual for your exact model and serial number. This page is independent and unofficial.