# Videojet E15008: Viscometer Empty Time Too Long

**Series:** Videojet 1580 / 1860 / 1880  \
**Source tier:** manual  \
**Confidence:** high  \
**Citation:** p. 9-13 — "(E15008) Viscometer Empty Time Too Long"  \
**Last checked:** 2026-11-21

## What it means

The viscometer failed to empty in time, so viscosity cannot be monitored.

## Likely causes

- Clogged viscometer drain
- Thick ink
- Blocked vent cross-connect
- Valve leaking
- Low-level probe fault
- Defective IMB

## What to check

- Contact your local Videojet Service representative

## Parts

- viscometer
- valve
- ink management board

## Consumables

- ink

## Source

- https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf

> Diagnostic guidance only. Verify against the service manual for your exact model and serial number. This page is independent and unofficial.