# Videojet E10681: Ink System Valve Current Too Low

**Series:** Videojet 1580 / 1860 / 1880  \
**Source tier:** manual  \
**Confidence:** high  \
**Citation:** p. 9-8 — "(E10681) Ink System Valve Current Too Low"  \
**Last checked:** 2026-11-21

## What it means

Valve drive current is too low for the number of valves in use.

## Likely causes

- Open circuit in one or more valves
- Defective IMB

## What to check

- Stop the jet and run a hardware valve test

## Parts

- ink system valves
- ink management board

## Consumables

- ink

## Source

- https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf

> Diagnostic guidance only. Verify against the service manual for your exact model and serial number. This page is independent and unofficial.