# Videojet E10672: Printhead 1 Valve Current Offset Out of Range

**Series:** Videojet 1580 / 1860 / 1880  \
**Source tier:** manual  \
**Confidence:** high  \
**Citation:** p. 9-7 — "(E10672) Printhead 1 Valve Current Offset Out of Range"  \
**Last checked:** 2026-11-21

## What it means

The printhead valve current offset measured at start-up is outside tolerance.

## Likely causes

- Erroneous offset calculated at boot
- Environmental extreme
- Short in one or more valves
- Defective MCB

## What to check

- Power-cycle to reset the offset
- Run a hardware self-test or valve test

## Parts

- printhead valves
- main control board

## Consumables

- Not listed in the source.

## Source

- https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf