# Videojet E10671: Ink System Valve Current Offset Out of Range

**Series:** Videojet 1580 / 1860 / 1880  \
**Source tier:** manual  \
**Confidence:** high  \
**Citation:** p. 9-7 — "(E10671) Ink System Valve Current Offset Out of Range"  \
**Last checked:** 2026-11-21

## What it means

The ink-system valve current offset measured at start-up is outside tolerance.

## Likely causes

- Erroneous offset calculated at boot
- Environmental extreme
- Short in one or more valves
- Defective IMB

## What to check

- Power-cycle to reset the offset
- Run a hardware self-test or valve test

## Parts

- ink system valves
- ink management board

## Consumables

- ink

## Source

- https://cdn.pimber.ly/public/asset/raw/604204e33fc1d2001bbaeea6/d48fefc9/62b5db2d2d2f5f4727000086/E12907_1.pdf

> Diagnostic guidance only. Verify against the service manual for your exact model and serial number. This page is independent and unofficial.